Plasma irradiation experimental system (normal conduction)

Main technical indicators:
The magnet system consists of a permanent magnet, a plasma source (cascaded arc plasma source), a vacuum chamber, a sample bench, a vacuum pump group, a vacuum gauge, a Langmuir probe and a power supply control system.
Model: XSMT-0.3T311
Working current: 460A
Central magnetic field: 3000Gs
Room temperature hole diameter: Φ311
Magnetic field uniform area: the center area Φ80mm*500mm cylinder uniformity is 4.5%.